More unsanitary conditions from February 17 Inspection:
Adequate hand washing facilities supplied & accessible Priority Foundation-6-301.11, Pf: Handwashing Cleanser, Availability.....No soap available at one of two handwash sinks in the Modern Margarita bar. Employee provided. Priority Foundation-6-301.12, Pf: Hand Drying Provision......No paper towels available at one of two handwash sinks at the Modern Margarita bar. Employee provided. Handwash sinks are those that are provided with splash guards, the other two sinks in the bar are dump sinks without splash guards. Both handwash sinks must be provided with soap and paper towels, regardless of frequency of use. This is a consecutive violation. A pattern of non-compliance may result in legal action. Corrected At Time Of Inspection49 Plumbing installed; proper backflow devicesPRIORITY VIOLATION-5-202.13, P: Backflow Prevention, Air Gap.....The end of the sprayer at the 3 compartment sink hangs below the overflow level of the sink. The spring arm is missing on the sprayer. Repair such that at least a one inch air gap exists. A re-inspection will occur on 1-24-17.Correct Prior To Reinspection54 Adequate ventilation & lighting; designated areas usedCore-6-303.11, C: Intensity-Lighting....None of the exhaust hood lights function. The panel-type light fixtures in the kitchen require 3 florescent bulbs each, but most of the light fixtures have one or more non-functioning bulbs. These non-functioning bulbs make the entire kitchen dim. Restore lighting to provide 20 - 50 foot candles of intensity.